I connected my custom c2000 320f28335 mcu board via sci_a with com port to simulink for xcp debugging, but there is time out error on connection.
Is there any specific hardware configuration?
matlab version 2022b.
the error is :
Could not connect to target application: XCP internal error: timeout expired, in response to XCP CONNECT command

1 Kommentar

ali
ali am 23 Aug. 2023
Sci-a connected to pc via USB to TTL device, on com port and I configured this port number in hardware configuration in simiulink and also I checked pin number of sci-a

Melden Sie sich an, um zu kommentieren.

 Akzeptierte Antwort

ali
ali am 26 Aug. 2023

0 Stimmen

in my case the problem was due to Gnd connection of board and USB to TTL device, I had not connected Gnd,
after I connect it, external mode works correctly

Weitere Antworten (0)

Kategorien

Mehr zu Deployment, Integration, and Supported Hardware finden Sie in Hilfe-Center und File Exchange

Produkte

Version

R2022b

Gefragt:

ali
am 20 Aug. 2023

Beantwortet:

ali
am 26 Aug. 2023

Community Treasure Hunt