xcp on serial Custom board c2000

95 Ansichten (letzte 30 Tage)
ali
ali am 20 Aug. 2023
Beantwortet: ali am 26 Aug. 2023
I connected my custom c2000 320f28335 mcu board via sci_a with com port to simulink for xcp debugging, but there is time out error on connection.
Is there any specific hardware configuration?
matlab version 2022b.
the error is :
Could not connect to target application: XCP internal error: timeout expired, in response to XCP CONNECT command
  1 Kommentar
ali
ali am 23 Aug. 2023
Sci-a connected to pc via USB to TTL device, on com port and I configured this port number in hardware configuration in simiulink and also I checked pin number of sci-a

Melden Sie sich an, um zu kommentieren.

Akzeptierte Antwort

ali
ali am 26 Aug. 2023
in my case the problem was due to Gnd connection of board and USB to TTL device, I had not connected Gnd,
after I connect it, external mode works correctly