How to calculate power using Simscape planetary gear block?
3 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
We are planning to calculate power by multiplying the torque value obtained from a SimScape planetary gear block with its angular velocity. We have connected a torque sensor and rotational sensor to the carrier output, but the torque value remains at zero. We would like to know how to correctly connect the torque sensor to obtain accurate torque values. Furthermore, if there is a method to calculate power by multiplying torque and rotational speed without using sensors, that would be even better. We are also interested in how to apply this to the Sun and Ring components for power calculations.
(I uploaded this model too.)
1 Kommentar
kyobum lee
am 20 Jul. 2023
Your carrier is fixed to the ground(or chassis) Why would you like to calculate Rotational speed and torque of carrier?
In my humble opinion(and others correct me if I'm wrong) but your sensors seems to be connected right.
As I didn't use simscape for long time so cannot remember exactly, but what is the source sending?
torque value? or speed value?
Akzeptierte Antwort
Jongil Lee
am 20 Jul. 2023
안녕하세요
구하시고 하는 토크 값은 Simscape 상에서 through variable 이기에 에너지가 토크센서를 관통해서 전달되어야 합니다.Rotational spring을 추가하거나 시스템의 구조를 다시 한번 확인해 보시기 바랍니다. 추가적으로 Power를 측정할 수 있는 블럭을 활용하시면 보다 편리하게 사용할 수 있습니다.
1 Kommentar
Weitere Antworten (0)