How can I set a initial value for input parameters in FMU?

27 Ansichten (letzte 30 Tage)
Shashank Mehta
Shashank Mehta am 13 Jun. 2023
Kommentiert: Julian am 8 Apr. 2024
I want to co-simulate the FMU in PowerFactory and want to assign initial value for the parameters, how can I do it while creating an FMU.

Akzeptierte Antwort

Satwik
Satwik am 14 Jun. 2023
When you create an FMU (Functional Mock-up Unit), you can define parameters with initial values in the FMU description file (modelDescription.xml). This file includes metadata about the FMU, such as the name of the model, the type of solver used, and the number and types of inputs and outputs.
Here's an example of how you can define a parameter with an initial value in the FMU xml description file:
<ScalarVariable
name="myParameter"
valueReference="1"
variability="parameter"
initial="1.0" />
  3 Kommentare
Julian
Julian am 8 Apr. 2024
You have to unzip the .fmu file to see the ModelDescription.xml.
Julian
Julian am 8 Apr. 2024
@Satwik is there a way to set the initial values of variables in <ModelVariable><start> attribute when exporting the FMU with FMI version 3.0? Changing the ModelDescription.xml after exporting it as Standalone FMU seems not to be the best practice to me.