Import a signal from workspace to simulink

1 Ansicht (letzte 30 Tage)
Darren
Darren am 3 Mai 2023
Bearbeitet: Andreas Goser am 3 Mai 2023
I am doing motion control and I have imported a signal from SPiiPlus MMI Application into .m file to do a simulation
It is a position reference and i need to use that reference position for my simulation
i tried 'From workspace' block, 'Signal from workspace' block and output to the 'scope' block and I am unable to get the desired reference result

Antworten (1)

Andreas Goser
Andreas Goser am 3 Mai 2023
Bearbeitet: Andreas Goser am 3 Mai 2023
My guess is the From Workspace block is missing time values as your variable CH3 only has data values.
  2 Kommentare
Darren
Darren am 3 Mai 2023
I see. If my period is 100sec, is there anyway to insert it in? Or are there a different way to get the position profile?
Andreas Goser
Andreas Goser am 3 Mai 2023
Bearbeitet: Andreas Goser am 3 Mai 2023
There are multiple options, see https://www.mathworks.com/help/simulink/slref/fromworkspace.html. Assuming your measurements are equidistant, you could create a time vector with the same size as CH3 and then concatenate both to a matrix the From Workspace block understands.

Melden Sie sich an, um zu kommentieren.