Hi,
I have a question regarding the parameter dialog box for the PMSM Simscape block. One of the parameters is "Back EMF Flat Top Area" for the Trapezoidal configuration. Is this the flat region (in electrical degrees) of the Phase back-emf or the Line-to-Line back emf waveform? I think it is the flat region of the Phase back-emf waveform, but I wanted someone to confirm this.
Regards, Ganga

Antworten (1)

Sabin
Sabin am 24 Jan. 2024
The "Back EMF Flat Top Area" refers to the flat region of the Phase back-EMF waveform when the motor is configured for a trapezoidal back EMF profile.