how to connect this Simulink signal from AnSoft block to VI measurement block? I want to change Simulink signal into electrical signal?
6 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen

0 Kommentare
Antworten (1)
Sabin
am 14 Feb. 2023
The Three-Phase V-I Measurement block is used to measure instantaneous three-phase voltages and currents in a circuit. When connected in series with three-phase elements, it returns the three phase-to-ground or phase-to-phase peak voltages and currents. The three measured phase-to-ground or phase-to-phase voltages. The Vabc output disappears when the Use a label parameter is selected or when the Voltage measurement menu is set to no. The three measured line currents. The Iabc output disappears when the Use a label parameter is selected or when the Current measurement menu is set to no. So, I assume either the measurements are set to no or 'Use a label' is selected. If you use a label then you can use a From block to get the Vabc/Iabc measurements. If you don't use a label in the VI measurement then you'll have Vabc/Iabc measurements as outputs from the VI measurement. You can then use the Vabc/Iabc signals in your S function as needed, you might need to demux the signals. I hope this helps.
0 Kommentare
Siehe auch
Kategorien
Mehr zu Switches and Breakers finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!