Simulink modeling solution needed

Hi
I got struck in one of the simulink model design. prob is like this.... I get some series of constant values from a signal, it will be compared with some constant[for ex. 1.1]. if true, a counter is decremented[first initialized to zero] and that counter value is compared with 2nd threshold value[for ex. -10]. if threshold is reached i.e -10 or more, i need to reset the whole set up to 0 starting from decrement counter.
all the design should be done in simulink only. thanks in advance

 Akzeptierte Antwort

Fangjun Jiang
Fangjun Jiang am 21 Okt. 2011

0 Stimmen

Use the "Discrete-Time Integrator" block from library Simulink>Discrete. It has an option to allow external reset.
Use the "Compare to Constant" block to compare your signal with a constant. Also, use the same block to compare the counter with -10 and then trigger the reset of the Integrator.
Or use a Unit Delay block, start off with this demo model, rtwdemo_counter.mdl.

2 Kommentare

spoon
spoon am 22 Okt. 2011
what if the signal is a series of constant numbers. ?
Fangjun Jiang
Fangjun Jiang am 22 Okt. 2011
It will be same.

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (0)

Kategorien

Produkte

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by