Fmu with “canBeInstantiatedOnlyOncePerProcess” = false
6 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
I would like to create an fmu from a simulink model where the “canBeInstantiatedOnlyOncePerProcess” fmu variable is set to false rather than true. Is there a way to set this?
1 Kommentar
Antworten (1)
Yash
am 23 Sep. 2024
Bearbeitet: Yash
am 23 Sep. 2024
The canBeInstantiatedOnlyOncePerProcess flag in modelDescription.xml can be set to true or false for a Simulink model with fixed-step solver by either:
1) Using CLI: By setting the value of parameter SupportMultiInstance as on or off in the function exportToFMU (https://www.mathworks.com/help/slcompiler/ref/exporttofmu.html#mw_543093a5-7db7-4a99-82fa-2ab09dbc03c6) The flag is set to false when this parameter is specified as on.
2) From GUI: By selecting the check box "Support multiple instantiation per process" in the Advanced tab of Export Model to Standalone FMU

This functionality seems to have been supported since MATLAB R2024b by MathWorks and is compatible with FMI 2.0 and 3.0 standards.