about nonvirtual subsystem,how to solve it
Ältere Kommentare anzeigen
Connections of the Physical Network cross nonvirtual boundaries. If any blocks in a Physical Network are within a nonvirtual subsystem, then all blocks of that network must be in the same nonvirtual subsystem. Either move affected blocks out of the nonvirtual subsystem, move network blocks into exactly one nonvirtual subsystem, or reconfigure affected nonvirtual subsystems to be virtual subsystems.
3 Kommentare
Saif Sayed
am 17 Aug. 2016
Hi, I encountered the same problem. Were you able to solve it?
Ammon McCarthy
am 16 Apr. 2020
Hi, I also have this problem. Was this taken care of?
Thirumala
am 4 Apr. 2025
Any solution?
Antworten (1)
MULI
am 15 Apr. 2025
0 Stimmen
The error you are observing "Connections of the Physical Network cross nonvirtual boundaries..." is a known limitation which can be found in the below MathWorks documentation link:
Instead, you can try one of the following solutions:
- Make all related subsystems virtual (Right-click the subsystem → Subsystem Parameters → Uncheck "Treat as atomic unit")
- Move all physically connected blocks into a single nonvirtual subsystem
- Move all physical network blocks to the top level of the model.