Filter löschen
Filter löschen

Battery SOC is showing 0 reading in scope while discharging

1 Ansicht (letzte 30 Tage)
Armaghan Arshad
Armaghan Arshad am 15 Jul. 2022
Beantwortet: Xiangchun am 20 Okt. 2023
i am trying the given model but i am not getting proper SoC graph its showing 0 throughout the execution the model, graph and setting of battery are given below kindly give feedback what actually wrong with the settings thanks

Antworten (1)

Xiangchun
Xiangchun am 20 Okt. 2023
Hi Armaghan,
The SOC physical signal from the Battery (Table-Based) block goes through PS-Simulink Converter before it becomes a Simulink signal that is suitable for display on the Scope. From the screenshot, it appears that there are two PS-Simulink Converters for the SOC signal converstion. Only one is needed. Please double check the model and connections to verify if that is indeed the case.
Best wishes,
Xiangchun