Defining pmsm parameters for delta configuration

2 Ansichten (letzte 30 Tage)
Jordan  Graham
Jordan Graham am 6 Jun. 2022
I am trying to define the parameters for a PMSM in delta configuration in SimScape. By considering the layout diagram for the wye wound configuration in the help window related to the block I can see that the phase-phase terminal resistance and inductance specified on the datasheet should be divided by 2 to define the 'per phase' resistance and axis inductances for the pmsm.
I am not so clear on defining these parameters for a delta wound configuration as there is no layout diagram for this, does the winding configuration influence how these parameters are defined? From looking at other delta wound layout diagrams I would be leaning towards not dividing these parameters by 2.

Antworten (1)

Dr Narayanaswamy P R Iyer
Dr Narayanaswamy P R Iyer am 6 Jun. 2022
The resistance and inductance values must be multiplied by 2/3 to get the per phase values for delta configuration. Thanks. DR. N P R IYER.

Communitys

Weitere Antworten in  Power Electronics Control

Produkte


Version

R2021a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by