How can I model the openeing of a 2-Way Directional Valve by different percentages?
2 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Andrews Kwkaye
am 18 Apr. 2022
Beantwortet: Yifeng Tang
am 24 Jun. 2022
How can I model the openeing of a 2-Way Directional Valve by different percentages? I am trying to model how water moves in a rig, and I want to know how the pressure and flow rate is affected by how open the valve is
0 Kommentare
Akzeptierte Antwort
Yifeng Tang
am 24 Jun. 2022
The way valves are modeled in the fluids domains is that it translates a spool position (S port input) to an orifice opening size. The orifice then defines the pressure drop vs flow rate characteristics. So now the question is what you mean by "different percentages".
If it means that at X% opening, the flow rate would be X% of the flow rate at max orifice area position, under the same pressure drop: what you can do is to assume X% of full spool travel from fully closed position == X% open. Construct a spool position vector, say 0-5mm with 0.5mm increments. Then you play with the elements in the orifice opening area vector at each opening position so that it gives you X% of max flow rate.
If by X% opening you mean the spool moves X% of full travel from the fully closed position, then there is likely a missing piece of information here: what is the flow rate at X% open compared to fully open? Some reference data will help you to set the opening area table/array in this case.
0 Kommentare
Weitere Antworten (0)
Siehe auch
Kategorien
Mehr zu Two-Phase Fluid Library finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!