Filter löschen
Filter löschen

Simcape onramp getting the error of block value

2 Ansichten (letzte 30 Tage)
Sudchai Boonto
Sudchai Boonto am 8 Apr. 2022
Kommentiert: PranayReddy B am 19 Mai 2022

Antworten (1)

Ganesh Gudipati
Ganesh Gudipati am 11 Apr. 2022
Hi,
The errorMultiple Solver Blocks connected to physical network. Each physical network must be connected to exactly one Solver Configuration block” generally arises when there are multiple solver blocks connected to the network.
I tired to reproduce the issue from my end.
In the first picture, notice that there two Solver Configuration blocks which causes the error. And it can be solved by removing one of the Solver blocks. But in the screenshot attached to the question I could see only one solver block. Check if the blocks are overlapped. If the issue is not solved, try to remove all the connections, and reconnect them.
  2 Kommentare
Sudchai Boonto
Sudchai Boonto am 13 Apr. 2022
Thank you for you helping.
My problem was not the issue of the Solve block but the isothermal liquid properies as show in the figure below. The volumetric fraction of entrained ... must set to 0.
PranayReddy B
PranayReddy B am 19 Mai 2022
thanks alot
you saved my entire day

Melden Sie sich an, um zu kommentieren.

Kategorien

Mehr zu Elements finden Sie in Help Center und File Exchange

Produkte


Version

R2022a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by