Simcape onramp getting the error of block value

Antworten (1)

Ganesh Gudipati
Ganesh Gudipati am 11 Apr. 2022

0 Stimmen

Hi,
The errorMultiple Solver Blocks connected to physical network. Each physical network must be connected to exactly one Solver Configuration block” generally arises when there are multiple solver blocks connected to the network.
I tired to reproduce the issue from my end.
In the first picture, notice that there two Solver Configuration blocks which causes the error. And it can be solved by removing one of the Solver blocks. But in the screenshot attached to the question I could see only one solver block. Check if the blocks are overlapped. If the issue is not solved, try to remove all the connections, and reconnect them.

2 Kommentare

Thank you for you helping.
My problem was not the issue of the Solve block but the isothermal liquid properies as show in the figure below. The volumetric fraction of entrained ... must set to 0.
thanks alot
you saved my entire day

Melden Sie sich an, um zu kommentieren.

Kategorien

Mehr zu Simscape Fluids finden Sie in Hilfe-Center und File Exchange

Produkte

Version

R2022a

Gefragt:

am 8 Apr. 2022

Kommentiert:

am 19 Mai 2022

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by