how to write hourly varying load consumption data in matlab code for ieee 33 bus system to get current values and losses
24 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
i am working on IEEE 33 bus system and i have static load data so that i want use dynamic data like hourly load consumption data to get current values and losses for proposed test system,hence i request please guide me to writing the code in matlab
2 Kommentare
Lonah Segera
am 4 Apr. 2023
Dear Saleh Ba-swaimi. Could you please help me, I am working on the IEEE 15 bus and I need to represent the bus load data in hourly format but I don't know how to do it.
Antworten (1)
Thomson Mtonga
am 28 Jun. 2023
Dear sameer mohammad,
For a start, try running the attached file "UntitledElpa". It plots the load variations as are given in:
clc;
clear all;
format long
Industrial = [6:1:18];
Residential = [2,3,4,5,19,20,21,22,23,24,25];
Commercial = [26,27,28,29,30,31,32,33];
mpc = case33Loss202;
mpc.bus(2,3)
LoadVariInd = [0.56;0.54;0.52;0.50;0.55;0.58;0.68;0.80;0.90;0.98;1.00;0.94;0.95;0.96;0.90;0.83;0.78;0.72;0.71;0.70;0.69;0.67;0.65;0.60];
LoadVariRes = [0.69;0.65;0.62;0.56;0.58;0.61;0.64;0.76;0.9;0.95;0.98;1;0.99;0.99;1;0.96;0.96;0.94;0.93;0.92;0.91;0.88;0.84;0.72];
LoadVariCom = [0.2;0.19;0.18;0.18;0.2;0.22;0.25;0.4;0.65;0.86;0.9;0.92;0.89;0.92;0.94;0.96;1;0.88;0.76;0.73;0.65;0.5;0.28;0.22];
for i=1:length(Industrial(1,:))
AA(i,:)=(mpc.bus(Industrial(1,i),3))*1e3;
BB(i,:)=(mpc.bus(Industrial(1,i),4))*1e3;
end
for i=1:length(Residential(1,:))
AA1(i,:)=(mpc.bus(Residential(1,i),3))*1e3;
BB1(i,:)=(mpc.bus(Residential(1,i),4))*1e3;
end
for i=1:length(Commercial(1,:))
AA2(i,:)=(mpc.bus(Commercial(1,i),3))*1e3;
BB2(i,:)=(mpc.bus(Commercial(1,i),4))*1e3;
end
P = sum(AA);
Q = sum(BB);
S = (P^2+Q^2)^0.5;
P1 = sum(AA1);
Q1 = sum(BB1);
S1 = (P1^2+Q1^2)^0.5;
P2 = sum(AA2);
Q2 = sum(BB2);
S2 = (P2^2+Q2^2)^0.5;
for j=1:length(LoadVariInd(:,1))
Demand(j,:)=LoadVariInd(j,:)*S;
Demand1(j,:)=LoadVariRes(j,:)*S1;
Demand2(j,:)=LoadVariCom(j,:)*S2;
end
E=max(Demand);
E1=max(Demand1);
E2=max(Demand2);
Demand=Demand/E;
Demand1=Demand1/E1;
Demand2=Demand2/E2;
graph=plot([1:length(LoadVariInd(:,1))],Demand, '-oy',[1:length(LoadVariInd(:,1))],Demand1, '-og',[1:length(LoadVariInd(:,1))],Demand2, '-ob');
legend('Industrial Load Profile', 'Residential Load Profile', 'Commercial Load Profile');
set(graph,'LineWidth',1.3);
xlabel('Time (h)');
ylabel('Demand (p.u.)');
xlim([1 24]);
ylim([0 1]);
grid on;
Optimal Placement and Sizing of D-STATCOM in Radial and Meshed Distribution Networks Using a Discrete-Continuous Version of the Genetic Algorithm By Cristian Mateo Castiblanco-Pérez, David Esteban Toro-Rodríguez, Oscar Danilo Montoya and Diego Armando Giral-Ramírez
4 Kommentare
sevgi
am 9 Okt. 2024
Dear Mr. Thomson
How can I perform a 24-hour power flow analysis (bus voltages, line currents, etc.) of a 33-bus radial distribution system?
Siehe auch
Kategorien
Mehr zu Power and Energy Systems finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!