interpn not working inside of a Simulink function
4 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
The following function call:
vs = getAeroCoefficientsForVTail( 0, -10 ); works when running on the command line.
But, when running untitled_20210b.mdl, the Embedded Simulink MATLAB function calling getAeroCoefficientsForVTail complains saying "wong number of input arguments.".
This is weird behavior, since calling the function outside of the Embedded Simulink MATLAB function works.
Help appreciated in this very confusing problem.
0 Kommentare
Antworten (1)
Pavan Guntha
am 24 Nov. 2021
Hi Julien,
The issue occurs because of the follwing line in the code 'getAeroCoefficientsForVTail.m':
% Line 91:
coefficients = reshape( interpn( alpha_s, beta_s, LUT, alpha_deg, beta_deg, 'linear', -1 ), [1, 71] );
% Specifically the issue is with the arguments to the 'interpn' function.
The following error message is shown when the function is run through both MATLAB/ Simulink:
"The number of input coordinate arrays must match the dimensions of the sample values."
Hope it helps!