Dear Mathworks Support,
How to set stator-rotor turns ratio of an induction motor (wound rotor)?
Dan
0 Kommentare
Antworten (1)
Sandip Kumar
am 7 Okt. 2014
I understand you are referring to this Asynchronous machine:
If so, the stator-rotor turn ratio is captured in the resistance and inductance of the Stator and Rotor.
They should follow the following equation:
Rr' = a^2 * Rs; Llr' = a^2 * Lls;
hence, mention your resistance and inductance accordingly.
Thanks, Sandip, MathWorks
1 Kommentar
Nguyen Huu Nam
am 5 Okt. 2017
In Matlab simulink usely Llr' = Lls, that's mean a = 1 ? But Rr' no equal Rs Thanks and best regard