How to collect last bits of data from background acquisition
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
function trial
s = daq.createSession('ni');
addAnalogInputChannel(s,'Dev1', 'ai0', 'Voltage');
% addDigitalChannel(s,'Dev1','port0/line11','InputOnly');
s.IsContinuous = true;
s.Rate = 100;
s.NotifyWhenDataAvailableExceeds = 100;
% s.DurationInSeconds = 10;
lh = addlistener(s,'DataAvailable', @plotData);
tic;
startBackground(s);
pause(5.2);
stop(s);
toc;
end
function plotData(src,event)
fprintf('Length = %d\n',size(event.Data,1));
end
Im trying to run the above code in R2014a with the session interface. While I am able to get access to the first five data chunks, the last chunk with ~20 data points is not accessible. Any idea why?
stop(s); stops the session and all associated hardware operations in progress. If your operation has acquired data and the DataAvailable event has not yet fired, the stop command will fire the event and deliver the data acquired up to that point.
4 Kommentare
Geoff Hayes
am 22 Aug. 2014
Bearbeitet: Geoff Hayes
am 22 Aug. 2014
That is surprising/disappointing especially given the description on how the stop function works...