Simulation hangs and crashes when changeing values of capacitors from 10e-6 to 10e-9
2 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Hello community,
I have the following problem with Simulink: the simulation generally works without problems. When I change the values of capacitors in my circuit in the range from 10e-6 to 10e-9, the simulation runs up to T= 0.199 from T=0.2 without errors and then Matlab/Simulink and my system hangs. After a short time, Matlab/Simulink crashes. After that, there is no error message or crash report. How can I find out what exactly causes this behavior and how to fix it?
Thank you for your comments :)
----------------------------------------------------------------------------------------------------
MATLAB Version: 9.8.0.1721703 (R2020a) Update 7
Operating System: Linux 4.19.0-17-amd64 #1 SMP Debian 4.19.194-3 (2021-07-18) x86_64
Java Version: Java 1.8.0_202-b08 with Oracle Corporation Java HotSpot(TM) 64-Bit Server VM mixed mode
-----------------------------------------------------------------------------------------------------
MATLAB Version 9.8 (R2020a)
Simulink Version 10.1 (R2020a)
Simscape Version 4.8 (R2020a)
Simscape Electrical Version 7.3 (R2020a)
0 Kommentare
Antworten (1)
Joel Van Sickel
am 20 Sep. 2021
Hello Luis,
the fact that it is crashing without a warning is a bug, can you share the model that crashes? On a side note, changing the capacitance to something that small will require a much smaller time step to simulate correctly. To assist with that, you can try changing your simulation relative (and absolute) tolerance to 1e-4 and 1e-5. Make sure to use ode23t or DAESSC as your solver.
Regards,
Joel
0 Kommentare