Data transfert between 2 subsystems with a different endianess.

8 Ansichten (letzte 30 Tage)
christian VALPARD
christian VALPARD am 7 Sep. 2021
Beantwortet: Animesh am 16 Apr. 2024
Hi,
Is it possible to have a model including only :
. 2 Subsystems with different endianess ?
. Communication between the 2 subsystems ?
Best regards
C. VALPARD

Antworten (1)

Animesh
Animesh am 16 Apr. 2024
Yes, it is feasible to incorporate two subsystems within Simulink, each employing a distinct endianness. To transition from one format to the other, you can leverage a MATLAB Function block, utilizing the swapbytes function for this purpose. Below is a sample function to assist in swapping the byte order:
function y = swapBytes(x)
% Interpret x as a uint32, then swap the bytes
x = typecast(x, 'uint32');
y = swapbytes(x);
end
I hope this helps.
Regards,
Animesh