Get exact value from Scope cursor in Simulink
30 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
I am using the vertical Cursors in a Scope window to find the signal value. However, the value only displays three significant numbers behind the comma. In my example, it shows 2.202e+07:
Can I get the signal value with more significant numbers somehow? The signal in this case is actually a uint32 signal where each bit represents something, so I need to get the exact uint32 value.
0 Kommentare
Akzeptierte Antwort
Sahil Jain
am 2 Sep. 2021
Hi Jonas. As of R2021a, it is not possible to increase the number of digits shown in the Scope block window. As a workaround, you can export the signals to the workspace (see "to workspace" block) and use the "format" function to set the format style to 'long' and print the values to the console.
2 Kommentare
Controls Engineer
am 2 Aug. 2023
Hi Sahil, is there a plan to meet this requirement in a future release? Given the number of views within the last 30 days, it would seem many people are disappointed in this loss of functionality and have searched for a solution. "to workspsace" is not a viable long term solution when needing to quickly analyze signals.