Pwelch and accuracy/number of points
2 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
George Lazaridis
am 14 Jul. 2014
Beantwortet: George Lazaridis
am 14 Jul. 2014
Hello, I have a signal sampled at 200Hz and when I perform the Pwelch method the returning frequency vector is till 100Hz as expected. My interest, though, is only at the frequencies 0-2Hz. Using xlim([0 2]) i can see the frequency content of interest but i want to use more points or maybe downsample my signal in order to get better accuracy at this frequencies. What do you propose?
0 Kommentare
Akzeptierte Antwort
Honglei Chen
am 14 Jul. 2014
Bearbeitet: Honglei Chen
am 14 Jul. 2014
If you only need to get more points in pwelch plot, I think increasing the number of FFT points in pwelch should do the trick.
0 Kommentare
Weitere Antworten (1)