PID Tune: Plant cannot be linearized. Why?

172 Ansichten (letzte 30 Tage)
Norman
Norman am 18 Jun. 2014
Kommentiert: Yashas S V am 21 Jun. 2021
Hello everyone,
I'm using simulink for simulating a cooling system. When I try to use the tune button on the PID it opens the tuning window and say:
Plant cannot be linearized.
Why is this happening?
The PID is doing is job. I've attached files.
Thank you very much for the help,
Norman

Akzeptierte Antwort

Arkadiy Turevskiy
Arkadiy Turevskiy am 18 Jun. 2014
The plant is linearized, but the linearization at t=0 is a gain of zero. Most likely this happens due to initial conditions in the model. You can ask the PID Tuner to linearize the model at a simulation snapshot of say t/2, when everything comes to steady state.
When you do that, the PID Tuner successfully linearizes the model and designs a PID controller.
Here are the snapshots of the steps using R2014a.

Weitere Antworten (1)

Norman
Norman am 19 Jun. 2014
Thank you very much for your answer, I've got what I have to do, but of I push the Re-linearize Closed Loop command, nothing happens.
I'm also working with the R2014a. Thank you for the support,
Norman
  7 Kommentare
Sharjeel Khan
Sharjeel Khan am 25 Dez. 2020
@Ayesha Sandamali i'm also simulating and grid connected PV system. I'm also facing the same problem can you help me with that please??
Yashas S V
Yashas S V am 21 Jun. 2021
Did you guys find anything? Please let me know if you find anything. Thanks in advance. (mail ID: ee18b040@iittp.ac.in)