Warnings for Non-existent Ports in a Matlab Function Block
2 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Hi all
I have a rather large model in Simulink. When it runs, it gives me a number of warnings similar to the following one:
Warning: Block 'SS_SplitSimulink_Model1/MATLAB I1/ SFunction ' output 'Inf'
for element 23 of output port 2 at minor time step 0.00016552
The strange thing is that the "MATLAB I1" block has only one output port. Is there any way in which a Matlab function block can have something like hidden ports? I get 'Inf" and "NaN" warnings, which is obviously quite troubling...
I apologise if I'm not giving enough info.
0 Kommentare
Akzeptierte Antwort
Niklas Nylén
am 1 Apr. 2014
Bearbeitet: Niklas Nylén
am 1 Apr. 2014
If the S-function was generated in Real time workshop/Simulink coder you can right click MATLAB I1 and select Look under mask. You should be able to see another "layer" where more outputs may exist.
3 Kommentare
Niklas Nylén
am 1 Apr. 2014
Bearbeitet: Niklas Nylén
am 1 Apr. 2014
Possibly outport 2 inside the S-function is only used for internal feedback and that is why there is no second outport on 'MATLAB I1'. As far as I know it is not possible to look inside an S-function unless you have access to the source code.
Weitere Antworten (0)
Siehe auch
Kategorien
Mehr zu Simulink Functions finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!