Discretizing a continuous state model for use in HIL

1 Ansicht (letzte 30 Tage)
Shyam
Shyam am 27 Nov. 2013
Bearbeitet: Shyam am 27 Nov. 2013
I have developed a model with continuous integrators. To discretize them, i had replaced them with discrete integrators,its working fine for Ts=1e-4, but i need to use Ts=1e-3; where its not getting simulated properly.
Anyone any suggestions,please post. Thanks

Antworten (1)

Azzi Abdelmalek
Azzi Abdelmalek am 27 Nov. 2013
You didn't precise how you replaced the other blocks, and I don't think you are doing the right thing. You also did not give enough information about your model (linear or not for example). If your model is linear you can use the function c2d to discretize it.
  3 Kommentare
Azzi Abdelmalek
Azzi Abdelmalek am 27 Nov. 2013
To be sure that you are doing the right thing, don't replace any block, just put a ZOH block with desired sample time after each output of your model (if your model is mimo) and before each input. Another important thing is: how did you choose the sample time, you can't set any sample time you want, it depends on the dynamic of your model, maybe 1e+3 is too large
Shyam
Shyam am 27 Nov. 2013
Bearbeitet: Shyam am 27 Nov. 2013
1e-3 as required by HIL, which works only with discretized models...with zoh at the input and fedback signal and with Ts=1e-3...works fine..

Melden Sie sich an, um zu kommentieren.

Kategorien

Mehr zu Simulink finden Sie in Help Center und File Exchange

Produkte

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by