Problem with connection
10 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Hi... I create a model but appear the next error:
"The following two blocks cannot be connected in series because they are modeled as current sources:
Block 1: Ideal Switch1 Block 2: Subsystem/Controlled Current Source
Add a high-value resistance in parallel with one of the two block. You can also specify high-value resistive snubbers if the blocks have a snubber device."
The Ideal Switch1 and the Subsystem/Controlled Current Source was SimPowerSystems but what resistor i use to correct the error?
1 Kommentar
Kaustubha Govind
am 27 Jun. 2011
I don't have any experience with SimPowerSystems but you could possibly set a large value for the "Snubber resistance Rs" parameter in the Ideal Switch dialog, as the error message suggests.
Akzeptierte Antwort
Nuno
am 29 Jun. 2011
4 Kommentare
Arnaud Miege
am 30 Jun. 2011
OK, try putting a resistor in parallel with the Controlled Current Source and see if that fixes it.
Weitere Antworten (3)
Arnaud Miege
am 28 Jun. 2011
Just use a Series RLC Branch in parallel with your ideal switch, but keep everything on the SimPowerSystems side (i.e. the resistor should between ports 1 & 2 of the ideal switch).
HTH,
Arnaud
Siehe auch