Main Content

Tune Block Parameters with Data Navigation

You can create tunable global parameters by embedding MATLAB® variables in block dialog boxes with data navigation. You can tune the parameters by changing the variable values during execution. In Connected IO mode or accelerator mode, Simulink® transfers the new values to the model that is being simulated. In Run in Kernel mode, Simulink transfers the new values to the real-time application that is running in the kernel mode process.

You can permanently store parameter objects and other external data in a data dictionary.

For this example, your goal is to minimize ringing in the transfer function.

This procedure begins with the square-wave transfer function model sldrtex_model. To open this model, in the MATLAB Command Window, type:

openExample('sldrtex_model')

This model opens in Connected IO mode.

Create Parameter Object

  1. Change to a working folder by using the cd command.

  2. Open sldrtex_model.

  3. Open the Transfer Fcn block parameters dialog box.

  4. Replace the existing value of Denominator coefficients ([1 70 10000]) with Dmp.

    Image of block parameters transfer function

  5. Click the Property Actions button after Dmp and select Dmp: Create.

  6. In the Value field, select Simulink.Parameter.

  7. In the Location field, select Base Workspace.

  8. Click Create.

    If the model is already in Run in Kernel mode, the data type defaults to Simulink.Parameter in the base workspace.

  9. In the Simulink.Parameter: Dmp dialog box, in the Value field, enter [1 70 10000].

    For the rest of the fields, take the defaults.

    Image of Simulink Parameters Dmp window

  10. In the Simulink.Parameter: DMP dialog box, click Apply and then click OK.

  11. In the Block Parameters: Transfer Fcn dialog box, click OK.

Tune Parameter Object

This procedure continues from the steps in Create Parameter Object.

  1. In the Simulink Editor, on the Desktop Real-Time tab, select Run in Real Time > Stop Time and change the Stop Time to Inf.

  2. Open the Scope block.

  3. Open the Transfer Fcn block parameters dialog box.

  4. Click the Property Actions button after Dmp and select Dmp (base workspace) > Open.

    Before you start execution, open this dialog box. You cannot open variable Dmp while the real-time application is running.

  5. To start execution, on the Desktop Real-Time tab, click Run in Real Time.

    Image of scope plot

  6. In the Simulink.Parameter: Dmp dialog box, change Value to [1 30 10000] and click Apply.

  7. Change the active dialog box by clicking on the model in the Simulink Editor, and then press Ctrl-D.

    Image of scope plot ripple

  8. Change Value to [1 180 10000] and click Apply.

  9. Change the active dialog box by clicking on the model in the Simulink Editor, and then press Ctrl-D.

    Image of scope plot ripple minimum

  10. On the Desktop Real-Time tab, click Stop.