Main Content

addobservable

Add observable expressions to SimData

Since R2020a

Description

example

sdout = addobservable(sdin,obsNames,obsExpressions) returns a new SimData object (or array of objects) sdout after adding the specified observables to the input SimData sdin. The inputs obsNames and obsExpressions are the observable names and their corresponding expressions. The number of expressions must match the number of observable names.

SimBiology® reevaluates existing observable expressions every time you call addobservable.

example

sdout = addobservable(sdin,obsNames,obsExpressions,'Units',units) specifies units for the observable expressions. The number of units must match the number of observable names.

Examples

collapse all

Load the Target-Mediated Drug Disposition (TMDD) model.

sbioloadproject tmdd_with_TO.sbproj

Set the target occupancy (TO) as a response.

cs = getconfigset(m1);
cs.RuntimeOptions.StatesToLog = 'TO';

Get the dosing information.

d = getdose(m1,'Daily Dose');

Scan over different dose amounts using a SimBiology.Scenarios object. To do so, first parameterize the Amount property of the dose. Then vary the corresponding parameter value using the Scenarios object.

amountParam = addparameter(m1,'AmountParam','Units',d.AmountUnits);
d.Amount = 'AmountParam';
d.Active = 1;
doseSamples = SimBiology.Scenarios('AmountParam',linspace(0,300,31));

Create a SimFunction to simulate the model. Set TO as the simulation output.

% Suppress informational warnings that are issued during simulation.
warning('off','SimBiology:SimFunction:DOSES_NOT_EMPTY');
f = createSimFunction(m1,doseSamples,'TO',d)
f = 
SimFunction

Parameters:

         Name          Value        Type            Units    
    _______________    _____    _____________    ____________

    {'AmountParam'}      1      {'parameter'}    {'nanomole'}

Observables: 

     Name         Type               Units      
    ______    _____________    _________________

    {'TO'}    {'parameter'}    {'dimensionless'}

Dosed: 

      TargetName                 TargetDimension                  Amount         AmountValue    AmountUnits 
    _______________    ___________________________________    _______________    ___________    ____________

    {'Plasma.Drug'}    {'Amount (e.g., mole or molecule)'}    {'AmountParam'}         1         {'nanomole'}


TimeUnits: day
warning('on','SimBiology:SimFunction:DOSES_NOT_EMPTY');

Simulate the model using the dose amounts generated by the Scenarios object. In this case, the object generates 31 different doses; hence the model is simulated 31 times and generates a SimData array.

doseTable = getTable(d);
sd = f(doseSamples,cs.StopTime,doseTable)
 
   SimBiology Simulation Data Array: 31-by-1
 
   ModelName:        TMDD
   Logged Data:
     Species:        0
     Compartment:    0
     Parameter:      1
     Sensitivity:    0
     Observable:     0
 

Plot the simulation results. Also add two reference lines that represent the safety and efficacy thresholds for TO. In this example, suppose that any TO value above 0.85 is unsafe, and any TO value below 0.15 has no efficacy.

h = sbioplot(sd);
time = sd(1).Time;
h.NextPlot = 'add';
safetyThreshold = plot(h,[min(time), max(time)],[0.85, 0.85],'DisplayName','Safety Threshold');
efficacyThreshold = plot(h,[min(time), max(time)],[0.15, 0.15],'DisplayName','Efficacy Threshold');

Postprocess the simulation results. Find out which dose amounts are effective, corresponding to the TO responses within the safety and efficacy thresholds. To do so, add an observable expression to the simulation data.

% Suppress informational warnings that are issued during simulation.
warning('off','SimBiology:sbservices:SB_DIMANALYSISNOTDONE_MATLABFCN_UCON');
newSD = addobservable(sd,'stat1','max(TO) < 0.85 & min(TO) > 0.15','Units','dimensionless')
 
   SimBiology Simulation Data Array: 31-by-1
 
   ModelName:        TMDD
   Logged Data:
     Species:        0
     Compartment:    0
     Parameter:      1
     Sensitivity:    0
     Observable:     1
 

The addobservable function evaluates the new observable expression for each SimData in sd and returns the evaluated results as a new SimData array, newSD, which now has the added observable (stat1).

SimBiology stores the observable results in two different properties of a SimData object. If the results are scalar-valued, they are stored in SimData.ScalarObservables. Otherwise, they are stored in SimData.VectorObservables. In this example, the stat1 observable expression is scalar-valued.

Extract the scalar observable values and plot them against the dose amounts.

scalarObs = vertcat(newSD.ScalarObservables);
doseAmounts = generate(doseSamples);
figure
plot(doseAmounts.AmountParam,scalarObs.stat1,'o','MarkerFaceColor','b')

The plot shows that dose amounts ranging from 50 to 180 nanomoles provide TO responses that lie within the target efficacy and safety thresholds.

You can update the observable expression with different threshold amounts. The function recalculates the expression and returns the results in a new SimData object array.

newSD2 = updateobservable(newSD,'stat1','max(TO) < 0.75 & min(TO) > 0.30');

Rename the observable expression. The function renames the observable, updates any expressions that reference the renamed observable (if applicable), and returns the results in a new SimData object array.

newSD3 = renameobservable(newSD2,'stat1','EffectiveDose');

Restore the warning settings.

warning('on','SimBiology:sbservices:SB_DIMANALYSISNOTDONE_MATLABFCN_UCON');

Input Arguments

collapse all

Input simulation data, specified as a SimData object or array of objects.

Names of the observable expressions, specified as a character vector, string, string vector, or cell array of character vectors.

Each name must be unique in the SimData object, meaning it cannot match the name of any other observable, species, compartment, parameter, or reaction referenced in the SimData object.

Example: {'max_drug','mean_drug'}

Data Types: char | string | cell

Observable expressions, specified as a character vector, string, string vector, or cell array of character vectors. The number of expressions must match the number of observable names.

Example: {'max(drug)','mean(drug)'}

Data Types: char | string | cell

Units for the observable expressions, specified as a character vector, string, string vector, or cell array of character vectors. The number of units must match the number of observable names.

Example: {'nanomole/liter','nanomole/liter'}

Data Types: char | string | cell

Output Arguments

collapse all

Simulation data with observable results, returned as a SimData object or array of objects.

Version History

Introduced in R2020a