Anzeigen nach

Frage


2017b simulink real time does not work on Advantech target computer
Hi! Though I am aware that MATLAB doesn't support custom target machines anymore in versions > 2018, I am using 2017b and hopin...

mehr als 5 Jahre vor | 0 Antworten | 0

0

Antworten

Frage


finding a single board computer compatible with simulink real time as a target pc
I couldn't find any article that explains the specs of a target computer. I'm still doing research to see my alternatives as a ...

fast 6 Jahre vor | 2 Antworten | 0

2

Antworten

Frage


Efficient way of loading a big structure in a simulink model toward a real time application
I have a large struct ~ 100 mb which stores a bunch of multidimensional arrays. The struct is read inside a matlab function in m...

mehr als 6 Jahre vor | 0 Antworten | 2

0

Antworten

Frage


different color codings (task assignments) in simulink model window and concurrent execution dialog box
Hello, It seems like I'm unable to assign tasks to correct models. Attached is a picture explaining the issue. I haven't e...

mehr als 6 Jahre vor | 0 Antworten | 0

0

Antworten

Frage


Implementation of structures defined as a parameter of (embedded) matlab function in Simulink for code generation applications
I know that Simulink structures (i.e., bus type objects aka non-virtual bus signals) are expensive to use in a time-critical app...

mehr als 6 Jahre vor | 2 Antworten | 0

2

Antworten

Frage


Data Transfer Settings Between Concurrent Tasks
I don't understand the difference between Ensure deterministic transfer (maximum delay) and Ensure deterministic transfer (minim...

mehr als 6 Jahre vor | 0 Antworten | 0

0

Antworten

Frage


Data synchronization of multi core Simulink RT programs designed in a producer-consumer architecture
Suppose a reference model, running at 1 khz, produces a bunch of data to be used by another reference model running at 500 Hz. ...

mehr als 6 Jahre vor | 0 Antworten | 0

0

Antworten

Frage


Multiple calls to interpn using same vectors
I do have a bunch of functions defined in the same domain but mapping to different values and I evaluate those functions with in...

mehr als 6 Jahre vor | 1 Antwort | 0

1

Antwort

Frage


Failure to solve symbolic equations in the form 'A*sin(x) + B*cos(x) == C'
Left hand side of this equation is known to admit A*sin(x) + B*cos(x) = R*cos(x-alpha) with R = sqrt(A^2+B^2) and alpha = arctan...

mehr als 6 Jahre vor | 1 Antwort | 0

1

Antwort

Frage


resuming fminsearch from where it's left
Hi everyone, I am using fminsearch on simulink real-time system. It's called once in a while not peridoically but can say ro...

fast 8 Jahre vor | 1 Antwort | 0

1

Antwort

Beantwortet
Simulink real time target boot kernel download problem
Tried reinstalling but didn't work

fast 8 Jahre vor | 0

Frage


Simulink real time target boot kernel download problem
Hello, Yesterday, during boot-up, my target pc started to give an error that I have never seen before. My target is config...

fast 8 Jahre vor | 1 Antwort | 0

1

Antwort

Beantwortet
baseboard serial receive fifo
I couldn't resolved the problem. Need help of anyone having the same issue

mehr als 8 Jahre vor | 0

Beantwortet
baseboard serial receive fifo
I also have an additional question. How does fifo receive interrupt level work? When I set it to half full or full, the proble...

mehr als 8 Jahre vor | 0

Beantwortet
baseboard serial receive fifo
UP! still having the issue !

mehr als 8 Jahre vor | 0

Frage


baseboard serial receive fifo
Hello, I'm using baseboard serial fifo out block to receive data @ 1kHz from an external device. The device sends a unique...

mehr als 8 Jahre vor | 3 Antworten | 0

3

Antworten

Frage


Problem with the simulink RT test model (slrtestmdl) : Reference to non-existent field `Details`
When I run slrtest, the system passes the first three tests. When it tries to build the test model, I receive an error saying R...

fast 9 Jahre vor | 0 Antworten | 1