Beantwortet
Modelling Torque Couplers in Simulink
The simplest way is to couple the two sources as in this example in Simscape Electrical: https://mathworks.com/help/sps/ug/ipms...

mehr als ein Jahr vor | 0

Beantwortet
how to change certain blocks parameters during simulation
If you want to change the parameters during simulation, you can use Variable Inductor to build your RLC. For Synchronous Machin...

mehr als ein Jahr vor | 0

Beantwortet
There is a problem with the Simscape Varistor Model
This has been adressed in the following answer: https://www.mathworks.com/matlabcentral/answers/1950263-problem-with-varistor-c...

mehr als ein Jahr vor | 0

Beantwortet
Green Hydrogen Production error using solar plant.
In the Solar Cell block you can specify the Number of series connected cells per string and Number of parallel-connected string ...

mehr als ein Jahr vor | 0

Beantwortet
Is there anyone here who can help me with Luenberger observer?(3Phase pwm converter)
To learn more about the Luenberger observer check the Simscape electrical built in block: https://mathworks.com/help/sps/ref/lu...

mehr als ein Jahr vor | 0

Beantwortet
Question about in house cc-ih circuit simscape implementaion(piezeelectric energy harvester circuit)
I can see you are trying to use the N-Channel MOSFET block from Simscape Electrical. This block is a high-fidelity implementatio...

mehr als ein Jahr vor | 0

Beantwortet
I want to design the loss calculation model of three phase inverter and motor using the FEM Parameterized PMSM, simultaneously.
You are trying to mix blocks from two different technologies, Simscape and Specialized Power Systems. This should be avoided as ...

mehr als ein Jahr vor | 0

Beantwortet
Having difficulty assigning block names in FEMM
FEMM software is not developed by MathWorks. Best to check the FEMM documentation for specific questions.

mehr als ein Jahr vor | 0

Beantwortet
senserless zero crossing back emf BLDC motor control in Simulink
Check out this Simscape Electrical example as a starting point in learning more about BLDC sensorless control: https://mathwork...

mehr als ein Jahr vor | 0

Beantwortet
Class D amplifier simulation model with Asynchronous delta sigma modulation
A good place to start is Simscape Electrical. Check out the existing Amplifiers circuitry: https://mathworks.com/help/sps/ampli...

mehr als ein Jahr vor | 0

Beantwortet
Discrepancy between simscape and analytical solution
Without a model is hard to tell what the problem may be. One thing I noticed is that you mix two different technologies, Simscap...

mehr als ein Jahr vor | 0

Beantwortet
How should I build the voltage part of the control part of the DC microgrid?
You can start with the Stand-Alone Solar PV DC Power System with Battery Backup example in Simscape Electrical. This example sho...

mehr als ein Jahr vor | 0

Beantwortet
DC motor built in Simulink different from Simpowersys
Firstly, the numerical values used in the custom block are not consistent with the Simscape implementation. The inductance value...

mehr als ein Jahr vor | 0

Beantwortet
Pulse generation from duty cycles in Space vector modulation
A good starting point is the Three-Phase Three-Level PWM Generator example in Simscape Electrical: https://mathworks.com/help/s...

mehr als ein Jahr vor | 0

Beantwortet
i want to Simulate power transformer with Internal fault on it i.e winding turn to turn fault or turn to earth fault??
Check out the Winding block in Simscape Electrical: https://mathworks.com/help/sps/ref/winding.html To model a fault in the Wi...

mehr als ein Jahr vor | 0

Beantwortet
how can you change the tap position of a Three-Phase OLTC Regulating Transformer (Phasor Type) programmatically?
Initial tap position is the description of the parameter. Parameter name is 'InitialTap'. Therefore to change it programatically...

mehr als ein Jahr vor | 0

Beantwortet
I Set desire Speed at 1500 rpm then Why Asynchronous Machine Speed in RPM Not Comming as per desire ?
The question is rather unclear. I suggest checking out this example in Simscape Electrical that shows how to control and analyze...

mehr als ein Jahr vor | 0

Beantwortet
Questions regarding the Park transformation block in Matlab & Simulink 2019a
The problem is that you use constant angle=0. This is not correct. As you have a 60 Hz system you can compute the electrical ang...

mehr als ein Jahr vor | 0

Beantwortet
Fractional Order Elements Simulation
Check out the Supercapacitor block in simscape Electrical: https://uk.mathworks.com/help/sps/ref/supercapacitor.html

mehr als ein Jahr vor | 0

Beantwortet
I am working on the "PMSM with Thermal Model" example of MATLAB but when i put the MOSFET in this problem i am getting the errors
You are attempting to model the system by combining to different technologies, Simscape and Specialized Power Systems. This shou...

mehr als ein Jahr vor | 0

Beantwortet
MATLAB as spice editor
There is no SPICE addon for MATLAB. You can still open SPICE files in MATLAB editor but will not be able to highlight specific S...

mehr als ein Jahr vor | 0

Beantwortet
IGBT SPICE models .lib file into Simulink using subcircuit2ssc
I do not get any error with the attached netlist. The error suggests that when running the subcircuit2ssc the argument filenam...

mehr als ein Jahr vor | 0

Beantwortet
PMSM (Five-Phase) Mutual Inductance Equations are Wrong!
This was indeed a discrepancy in the expressions for self-inductances. However, the other equations on the page are correct. Thi...

mehr als ein Jahr vor | 0

Beantwortet
Induction motor- Simulink model
Check this similar question: https://www.mathworks.com/matlabcentral/answers/99084-why-am-i-receiving-error-messages-about-sing...

mehr als ein Jahr vor | 0

Beantwortet
Use Simulink Simscape Electronic components to model power system
Simscape Electronic and Simscape Power System merged in 2019 and formed Simscape Electrical. There are two technologies that are...

mehr als ein Jahr vor | 0

Beantwortet
Is there a difference between average and switching model in term of stability?
Yes, it can affect the output, results, and stability margin because: Switching models capture high-frequency dynamics and tran...

mehr als ein Jahr vor | 0

Beantwortet
input current and voltage in a cuk converter in simulink
In Simscape Electrical you can use a Controlled Current Source to inject the desire current into the system. https://uk.mathwor...

mehr als ein Jahr vor | 0

Beantwortet
Is there any PQ analyzer tool in Simulink? Where can I find it?
To learn more about power quality and harmonic analysis check this: https://uk.mathworks.com/videos/what-is-3-phase-power-part-...

mehr als ein Jahr vor | 0

Beantwortet
I want to do small signal stability analysis of Kundur's two area system model using PSAT.When I assign one slack bus,get state variables for one of the synchronous generator among four.When two slack bus,system is not responding.how to solve this?
Power System Analysis Toolbox (PSAT) is not developed by MathWorks. Best to check the PSAT documentation for specific questions....

mehr als ein Jahr vor | 0

Beantwortet
How to do small signal stability analysis of a multi machine system(four machine-eleven bus-two area system) using PSAT toolbox in MATLAB?
Power System Analysis Toolbox (PSAT) is not developed by MathWorks. Best to check the PSAT documentation for specific questions....

mehr als ein Jahr vor | 0