![photo](/responsive_image/150/150/0/0/0/cache/matlabcentral/profiles/10454084_1522136210118_DEF.jpg)
Varunjith Vijayan
Followers: 0 Following: 0
Statistik
RANG
40.789
of 297.016
REPUTATION
1
BEITRÄGE
16 Fragen
2 Antworten
ANTWORTZUSTIMMUNG
43.75%
ERHALTENE STIMMEN
1
RANG
of 20.419
REPUTATION
N/A
DURCHSCHNITTLICHE BEWERTUNG
0.00
BEITRÄGE
0 Dateien
DOWNLOADS
0
ALL TIME DOWNLOADS
0
RANG
of 157.687
BEITRÄGE
0 Probleme
0 Lösungen
PUNKTESTAND
0
ANZAHL DER ABZEICHEN
0
BEITRÄGE
0 Beiträge
BEITRÄGE
0 Öffentlich Kanäle
DURCHSCHNITTLICHE BEWERTUNG
BEITRÄGE
0 Highlights
DURCHSCHNITTLICHE ANZAHL DER LIKES
Feeds
How to run simulation and harware simultaneously
Hello Mark, Is that mean I have to use only the supported hardware like raspberry pi? I would like to know about the setting u...
mehr als 6 Jahre vor | 0
Frage
Baseline criteria in Test Manager: Is there any method to recapture the baseline criteria and replace the .mat file?
I am having more than 100 test cases for a model. When I make any changes to the main model the baseline criteria has to be repl...
mehr als 6 Jahre vor | 1 Antwort | 0
1
AntwortFrage
How to run simulation and harware simultaneously
I am having a model which is having statecharts inside it. I want to run hardware with the generated code and I want to visualiz...
mehr als 6 Jahre vor | 2 Antworten | 0
2
AntwortenStateflow: Output appears after some time/steps for a function call
The issue was with the sampling time used was different with the chart which is calling the function and the chart containing th...
mehr als 6 Jahre vor | 0
| akzeptiert
Frage
Stateflow: Output appears after some time/steps for a function call
I am using stateflow diagrams for a model and it is having multiple statecharts. The statecharts are having graphical functions ...
mehr als 6 Jahre vor | 1 Antwort | 0
1
AntwortFrage
How to compare logged signals in Test Manager results of different runs of same test harness?
In the simulink test manager I have not found the compare option(Something like the compare in Simulation data inspector). Ho...
fast 7 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Comparing output of different simulink model versions - Simulink Test
Is there any method to compare the output of different model versions using Test manager? I have several output signals which m...
fast 7 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Array of Busses in StateChart - Not able to extract the complete variable values in Stateflow
I am using Array of Bus as the input to a Statechart. I am not able to extract the complete values of variable 'a' in the state ...
fast 7 Jahre vor | 0 Antworten | 0
0
AntwortenFrage
Empty Sim Output when running in Parallel mode
When I run the Tests in parallel mode, Some of the output is not logging(Sim Output) is empty. But in normal run everything is l...
fast 7 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Custom criteria in Test Manager- Is there any way to get signal by name?
Now I am using the following code. In the following code I am using the index for getting the signal. Is there any method to get...
fast 7 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Matlab function calls in State chart during the 'exit' and 'transition' are not working
1. The function calls during the 'exit' and 'transition' are not working. In the attached model, I am receiving the values 1 and...
fast 7 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Simulink test manager 'Parallel Test Execution' is stopping with error
I want to decrease the time of Simulation for running 30 Test harness. I installed 'Parallel Computing tool box' and enabled 'Pa...
fast 7 Jahre vor | 1 Antwort | 1
1
AntwortFrage
Test harness location/ working of harnessinfo xml file
In the harnessinfo xml file the Directory is not specified for any of the harnesses. How the simulink is locating the Test har...
fast 7 Jahre vor | 1 Antwort | 0
1
AntwortFrage
What are the methods for synchronization/merging of Test harness's to new main model?
What are the methods to merge Test Harness with the newer version of the model when multiple developers are working on the devel...
etwa 7 Jahre vor | 2 Antworten | 0
2
AntwortenFrage
Detection of change of values on single step in Test sequence
In my model one of the signal value will have different values in single step itself. In test sequence transition I tried to det...
etwa 7 Jahre vor | 0 Antworten | 0
0
AntwortenFrage
Importing Excel data into Simulink for giving as input signal - Contains Enumeration values also
I want to import the data from Excel file to Simulink. Is it possible to import and save to .mat file in which the excel input c...
etwa 7 Jahre vor | 1 Antwort | 0
1
AntwortFrage
What are the methods available in Simulink Tes for giving inuput and getting output from a test sequence or test manager?
I had seen how to give input using the Excel files in Test Manager. Is there any method to export into excel from the Test asses...
etwa 7 Jahre vor | 1 Antwort | 0
1
AntwortFrage
Simulink Test customCriteria - structRefFromNonStruct error
I am logging the data to monitor the active step of Test sequence block to workspace. I tried to use this logged data in CustomC...
etwa 7 Jahre vor | 0 Antworten | 0