Simulink block handles change

2 Ansichten (letzte 30 Tage)
Alexander Boll
Alexander Boll am 14 Jul. 2021
Beantwortet: Alexander Boll am 15 Jul. 2021
I am analyzing Simulink models programmatically. For this I need to give every block an ID. I thought about using a block's handle for this -- e.g. the handle "2.000122070312500" for the block "data_in". My problem is, that these handles actually change each time a model is loaded with "load_system", destroying my IDs. After a clean Matlab restart, the handles are restored again, indicating there is some cache for handles.
Is there a way to clear the handle cache, so that handles will be reset and usable as IDs?
Is there another system to give each block an ID or should I just write my own?

Akzeptierte Antwort

Alexander Boll
Alexander Boll am 15 Jul. 2021
I found out, that a block's property 'Name' cannot be duplicated in the same subsystem. This means, that unique IDs can be given by using all the parent subsystems of a block plus it's name. As subsystems are also just blocks, this means, the parent hierarchy is duplicate free, as well.
E.g. the blocks called "Add1", "Add2" and "Clock" in the subsystems "Main/Precomputation" may be given the unique IDs "Main/Precomputation/Add1", "Main/Precomputation/Add2", "Main/Precomputation/Clock".
I did not yet find a way to clear the handle cache, but this way, I don't need to.

Weitere Antworten (0)

Kategorien

Mehr zu Modeling finden Sie in Help Center und File Exchange