How can I resample 3051.7578Hz data in 1000Hz?

5 Ansichten (letzte 30 Tage)
Soo Hyun Park
Soo Hyun Park am 12 Jul. 2021
Bearbeitet: Soo Hyun Park am 13 Jul. 2021
I have a set of time series sampled at 3051.7578Hz. I want to resample the data in 1000Hz (in millisecond resolution). What would be a good way? It seems that "resample" function only deals with a time series collected in a fixed rate (i.e. take only integers for sampling rate input). Should I design a sort of filter?

Akzeptierte Antwort

Walter Roberson
Walter Roberson am 12 Jul. 2021
resample(signal, 10000000, 30517578)

Weitere Antworten (1)

Jonas
Jonas am 12 Jul. 2021
use the interp1() function, it can also deal with non uniformly sampled data