How can I resample 3051.7578Hz data in 1000Hz?
7 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Soo Hyun Park
am 12 Jul. 2021
Bearbeitet: Soo Hyun Park
am 13 Jul. 2021
I have a set of time series sampled at 3051.7578Hz. I want to resample the data in 1000Hz (in millisecond resolution). What would be a good way? It seems that "resample" function only deals with a time series collected in a fixed rate (i.e. take only integers for sampling rate input). Should I design a sort of filter?
0 Kommentare
Akzeptierte Antwort
Weitere Antworten (1)
Jonas
am 12 Jul. 2021
use the interp1() function, it can also deal with non uniformly sampled data
0 Kommentare
Siehe auch
Kategorien
Mehr zu Multirate Signal Processing finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!