Test Sequence - Sample Time period

17 Ansichten (letzte 30 Tage)
Giuseppe Narracci
Giuseppe Narracci am 24 Jun. 2021
Bearbeitet: Srijith Kasaragod am 30 Aug. 2021
Hello,
I am using a Test Sequence block because I want to stimulate another block in a Test Harness but I have an error in Simulink Test Manager when I run the simulation test because the sample time period of the Test Sequence Block is 0.2 and It requires that the fixed-step size in the model must be a multiple of 0.2. Why?
How can I change the sample time period of test sequence? For example 0.001 s ?

Akzeptierte Antwort

Srijith Kasaragod
Srijith Kasaragod am 30 Aug. 2021
Bearbeitet: Srijith Kasaragod am 30 Aug. 2021
As per my understanding, you have chosen fixed-step solver to run the test harness with a step size of 0.5 and then chosen a sample time of 0.2 for your test sequence block. This results in an error as a fixed step size of 0.5 will not be able to cover the rate of execution of test sequence block since 0.2 is less than 0.5. The sample time of all blocks in the model has to be a multiple of solver step size. Alternately, you can also choose a variable-step solver to execute your test harness, by which the solver will automatically choose time steps to cover step size requirements of all blocks included.
Sample time of test sequence block can be modified by opening configuration parameters in the test sequence editor.
Refer this link to read more about sample time and its different types.

Weitere Antworten (0)