Voltage Measurement block error

40 Ansichten (letzte 30 Tage)
Mahdi Zolfaghari
Mahdi Zolfaghari am 23 Jul. 2013
How to remove this error: Input two of Voltage Measurement block Three-Phase V-I Measurement' is not properly connected to the network.
  5 Kommentare
MD SAIF MALIK
MD SAIF MALIK am 30 Nov. 2019
can you please ellaborate sir, how you remove this error
Uttam Reddy Pailla
Uttam Reddy Pailla am 18 Jun. 2021
Please let me know. Even i am facing the same issue

Melden Sie sich an, um zu kommentieren.

Akzeptierte Antwort

dpb
dpb am 24 Jul. 2013
Make the proper connection...
No can help w/o any other info--the message says the 2nd of the three inputs isn't actually connected to anything so the problem is upstream from there.

Weitere Antworten (5)

ARPAN MALKHANDI
ARPAN MALKHANDI am 10 Jan. 2018
Provide proper grounding of the source and the loads

lal mohammed
lal mohammed am 28 Apr. 2015
i have a same problem with upfc ..can any 1 help me with this project!!

srinath r
srinath r am 30 Mär. 2016
Voltage Measurement
if true
% code
end

amogha
amogha am 23 Jun. 2016
Connect the load and ground it.

Nida Riaz
Nida Riaz am 16 Mär. 2017
Hello; What is the main difference between UPFC (Phasor Model) and UPFC (Detailed Model)? Please Guide Me. Thank You