Simscap Scope shows wrong data.
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
Muhammad Qaisar Ali
am 26 Apr. 2021
Beantwortet: Joel Van Sickel
am 21 Mai 2021
I am simulating an RL Circuit.
when i take simulation time 10 ses, the graph on scope is nonsence.
if anyone know, how to fix it. please let me know.
Best Regards.
3 Kommentare
Mohammadreza Adib
am 1 Mai 2021
hi
open scope setting and uncheck first line in the last tab. it's about storing point. besides it's better to attache a photo to show your problem.
Akzeptierte Antwort
Joel Van Sickel
am 21 Mai 2021
Hello Muhammad,
this issue is likely not the scope, but the simulation results. The easiest explanaion of why the results don't make sense is that too large a time step is being used to plot them well. The results can actually be correct, but look wrong because of the large time step. Please set the maximum step size to a small value and your scope data may clean up. If that doesn't work, then something is probably wrong with the model or solver settings such that the simulation is not converging.
Regards,
Joel