Different results from radial averaging and averaging along x axis of fft2
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
I have an image(which is a height profile), and I apply 2D fft (fft2) on the data. Then I compute 2D power spectrum:
win=tukeywin(N,0.25)*tukeywin(M,0.25)';
z_win=z.*win;
Hm=fft2(z_win);
Cq=(a^2/(2*pi*N)^2).*((abs(fftshift(Hm))).^2);
Now, I radially average my power spectrum in order to get a 1D power spectrum from the 2D data.
Q1 : Why the value obtained here, differs with the value I gain if I do average data in x or y direction.
Q2 : What is the unit for radially averaged PSD? I should mention that the unit of my PSD is m^4. Is it m^4 or m^3 ? why? [frequency unit : 1/m]
0 Kommentare
Antworten (1)
Matt J
am 10 Jun. 2013
Bearbeitet: Matt J
am 10 Jun. 2013
Q1: Because the PSD is not circularly symmetric? Is there a reason to expect it to be?
Q2: m^4. Averaging over quantities should not change their units, because it is done by adding things up with dimensionless weighting coefficients.
5 Kommentare
Matt J
am 11 Jun. 2013
I don't really understand what you're saying these results reveal/explain. If your PSD is perfectly circularly symmetric, as you claim, I would expect to see identical results along x and y, possibly differing by floating point noise.