Issue with fixed point code generation
Ältere Kommentare anzeigen
Hi,
In fixed point model, inputs values are provided as 60,110,150,160,20,166,130. Expected result is 200 and it is shown exactly in simulation result.
But in generated code, the input values are displayed as 503316480,922746880,1258291200,1342177280,167772160,1392508928,1090519040 correspondingly. Result is displayed as 1677721600 instead of 200.
Please provide feedback on this.
Antworten (1)
Muruganandham Subramanian
am 28 Mai 2013
Bearbeitet: Muruganandham Subramanian
am 28 Mai 2013
Hi,
In fixedpoint operation, you might used scaling either binary point or slope and bias, So the value which you given as i/p(depends scaling value) and o/p (depends scaling value) should be divided finally.
e.g..
- if you are giving 60 as i/p using binary point scaling to 2^30 will given as 64424509440 (scaled value).
So finally If you divide by the scaled value, you can get your expected result
i.e.
Exp.result=Actualresult/Scaled value
3 Kommentare
Muruganandham Subramanian
am 28 Mai 2013
See.. here in your i/p and o/p you may used scaling value of 2^23 (Binary point). so that, By applying my above formula, you can get the result
RAVINDRANATH REDDY SUDA
am 28 Mai 2013
Muruganandham Subramanian
am 29 Mai 2013
If this answer helped you, Vote/Accept the answer..
Kategorien
Mehr zu Simscape Electrical finden Sie in Hilfe-Center und File Exchange
Produkte
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!