I want my input signal only two run for a specific time say from [5 sec to 20 secs ] when my simulation time is 100 secs,, is there any way to do this

Antworten (1)

Pavan Guntha
Pavan Guntha am 25 Mär. 2021
You may try to solve using the following steps:
1) Use clock block to get the current simulation time.
2) Append a combinational logic to actually compare current simulation time with your time of interest.
3) Use an enabled subsystem to appropriately route the signal to output with output signal of step 2 as control signal to this block.
Here's an illustration of these steps:
As depicted in the scope, the signal (here sine signal is taken as an example) is routed to the output only in the time slot of interest.
  2 Kommentare
NIHAD MOHAMED ALI
NIHAD MOHAMED ALI am 27 Mär. 2021
how do i invoke this >=5 or <=20 blocks?
Pavan Guntha
Pavan Guntha am 29 Mär. 2021
You can refer to the compare to constant block documentation for more details.