Block IO Outport Code Generation

6 Ansichten (letzte 30 Tage)
Anand Rangaramu
Anand Rangaramu am 3 Mai 2013
I have a s function with output port. The output of the port is stored as Block Signals (auto storage) and its defined by function \rtw\c\tlc\mw\commonhdr_blkiolib.tlc
How to change the output port character not to generate this temporary variable?
  3 Kommentare
Anand Rangaramu
Anand Rangaramu am 7 Mai 2013
I could change the behavior by adding below functions. Not the best solution but improved memory by lot
ssSetOutputPortReusable(S, 0, 1)
ssSetInputPortOverWritable(S, 0, 1);
Kaustubha Govind
Kaustubha Govind am 7 Mai 2013
Yes, that is what I was going to suggest. Could you explain what your ideal solution would be?

Melden Sie sich an, um zu kommentieren.