How to set different timesteps (sample time) for different subsystems?
Akzeptierte Antwort
MathWorks Support Team
am 25 Jan. 2025
Bearbeitet: MathWorks Support Team
am 3 Feb. 2025
You can do this by right-clicking on a subsystem->Block Parameters->Check the option 'Treat as atomic unit'. This should enable the sample time field in the block parameters. You can use this to set different sample times.
Note
: If the model contains a mix of continuous and discrete elements, then atomic subsystems won't work. In that case, use the Model Discretizer. To access the release-specific documentation for Model Discretizer in MATLAB R2020a, execute the following command in the command window:
>> web(fullfile(docroot, 'simulink/ug/model-discretizer.html'))
For information regarding the current release, please visit the following link: