How to set different timesteps (sample time) for different subsystems?

26 Ansichten (letzte 30 Tage)
How to set different timesteps (sample time) for different subsystems?
 

Akzeptierte Antwort

MathWorks Support Team
MathWorks Support Team am 25 Jan. 2025
Bearbeitet: MathWorks Support Team am 3 Feb. 2025
You can do this by right-clicking on a subsystem->Block Parameters->Check the option 'Treat as atomic unit'. This should enable the sample time field in the block parameters. You can use this to set different sample times.
Note
: If the model contains a mix of continuous and discrete elements, then atomic subsystems won't work. In that case, use the Model Discretizer. To access the release-specific documentation for Model Discretizer in MATLAB R2020a, execute the following command in the command window:
>> web(fullfile(docroot, 'simulink/ug/model-discretizer.html'))
For information regarding the current release, please visit the following link: