GigE Camera Error: Unable to set PacketSize
14 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
I'm trying to connect a GigE camera through a pleora PT1000 IP engine. I'm using Matlab 2012a. I'm getting an error of "gige: Unable to set PacketSize" when trying to preview or use getsnapshot. I've seen on a previous thread the same problem using 2010. The help there has not solved my problem. Any help would be greatly appreciated.
1 Kommentar
jonathan
am 25 Jul. 2013
I'm getting this same exact issue with the same pleora device. Have you found a solution to this yet?
Antworten (1)
Evan
am 25 Jul. 2013
Bearbeitet: Evan
am 25 Jul. 2013
Have you tried setting the Packet Size property for your camera? Outside of matlab, you should make sure Jumbo Frames are enabled and set the value to the maximum allowed by your network card by going to:
Control Panel > Device Manager > Network Adaptors > Network Card Name > Advanced > Jumbo Frames
Then, in matlab, set 'PacketSize' to that value:
src.PacketDelay = value;
2 Kommentare
jonathan
am 26 Jul. 2013
I did this, but forgot to set PacketSize in matlab as well. After imaqreset, it worked like a charm.
Siehe auch
Kategorien
Mehr zu GigE Vision Hardware finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!