Filter löschen
Filter löschen

Increasing xcorr() resolution

4 Ansichten (letzte 30 Tage)
Patrick Tamellini
Patrick Tamellini am 27 Apr. 2011
Hello,
Is there a wa y to increase the "resolution" of xcorr?
Something like zero padding for the fft()
Thanks,
Patrick

Akzeptierte Antwort

Daniel Shub
Daniel Shub am 28 Apr. 2011
Zero padding will increase the frequency resolution (i.e., reduce the spacing between frequency components), but does not affect the temporal resolution (the time between samples). The resample function increases the temporal resolution, but does not affect the frequency resolution.
a = [0, 0, 1, 0, 1, 0, 0];
b = [0, 0, 1, 1, 1, 0, 0];
upFactor = 10;
aUp = resample(a, upFactor, 1);
bUp = resample(b, upFactor, 1);
[r, lags] = xcorr(a, b, 'coeff');
[rUp, lagsUp] = xcorr(aUp, bUp, 'coeff');
lagsUp = lagsUp/upFactor;
plot(lags, r, 'b', lagsUp, rUp, 'r');
It you do not want a normalized cross-correlation, you will need to scale rUp.

Weitere Antworten (0)

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by