Can't solve simulation errors in FOC model (Simulink 2020a)
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
Hi everyone,
I am trying to develop an FOC algorithm (see screenshots attached) using the Motor Control Blockset in Simulink but I am getting the following errors (see screenshot attached). I don't know waht I am doing wrong since I fed my d and q currents to my Discrete PI controllers and fed the results straight into my Inverse Park Transform. I don't know how to solve this and any help would be greatly appreciated.
P.S. I have attached my FOC Simulink file below
0 Kommentare
Antworten (1)
Joel Van Sickel
am 1 Sep. 2020
Hello Jefazo,
your simulink lines can be vectors. So a single line can have a vector with 4 elements in it. These dimensions need to line up when connecting to subsystem. Your particular issue is that you are taking the phase current from the motor, which is a vecotr of dimension 3, and splitting it in a demux as if it is a signal of dimension 2. because of this, you are actually passing 2 values into the beta value of your clarke transform. You need to demux the phase currents into 3 values, and terminate phase current C.
Regards,
Joel
0 Kommentare
Siehe auch
Kategorien
Mehr zu C2000 Microcontroller Blockset finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!