Test Real-Time Application Error when build

1 Ansicht (letzte 30 Tage)
Luke Wheadon
Luke Wheadon am 15 Jan. 2020
Kommentiert: Luke Wheadon am 27 Jan. 2020
I am running Matlab 2019b with a Speedgoat baseline real time target machine.
I am trying to follow the simulink real time - simulink test example here:
When I get to step 9 I recieve this error:
Error due to multiple causes. Error while generating code for chart Test Assessment Block. Error occurred in 'ex_slrt_slt_osc_Harness1/Test Assessment Block'.
What does this mean and how can i overcome it?

Akzeptierte Antwort

Mohan Feng
Mohan Feng am 21 Jan. 2020
The error details should be shown in Diagnostic Viewer. Is the error related to block input/output size, dimenstion or non-scalar? If so, can you inspect the data defined in the Test Assessment block ("Int1" and "SigGen"). The size of both "Int1" and "SigGen" should be 1 instead of 2, since Demux is used. Can you change the size of the data defined to 1 and try again?
  1 Kommentar
Luke Wheadon
Luke Wheadon am 27 Jan. 2020
Thank you for your response, Changing the size of "Int1" and "SigGen" to 1 fixed the issue.

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (0)

Kategorien

Mehr zu Real-Time Simulation and Testing finden Sie in Help Center und File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by