trigger block in simulink

6 Ansichten (letzte 30 Tage)
Rahul kumar
Rahul kumar am 4 Sep. 2012
I need to have a trigger block, which should trigger only one block at a time.
For example
I have 2 blocks A , B connected to the trigger block T, this triggering block T should trigger one of these A, B blocks at different instances. i.e trigger A at instant 0, A at instant 1, B at instant 2, A at instant 2 and so on.
which triggering block should i use?
And should i use any code to have this timed triggering
waiting fr ur valuable response
Thank you
  3 Kommentare
Rahul kumar
Rahul kumar am 5 Sep. 2012
it should fire contiously.. as i am trying to convert a synchronous data flow graph into a synchronous block diagram..!
when A block is triggered should produce some tokens ( 2 for my model) when B block is triggered should consume some tokens ( 3 for my model)
Rahul kumar
Rahul kumar am 5 Sep. 2012
Bearbeitet: Rahul kumar am 5 Sep. 2012
So like this i need to form a producer-consumer model!! the trigger can be in any order.!
But preferably A,A,B,A,B because when A is fired twice (2+2 tokens produced), it is sufficient for B to get 3 tokens from double firing of A, then so on.

Melden Sie sich an, um zu kommentieren.

Akzeptierte Antwort

TAB
TAB am 5 Sep. 2012
Bearbeitet: TAB am 5 Sep. 2012
[Edited]
Please see the model snapshot below:
  4 Kommentare
Rahul kumar
Rahul kumar am 5 Sep. 2012
Yes the trigger sequence is as expected!! thank you,
And which block did you use for A, B is it triggered subsystem block?
TAB
TAB am 5 Sep. 2012
Bearbeitet: TAB am 5 Sep. 2012
Yes it is triggered subsystem with rising edge trigger type.
Initially at t=0, output of unit delay block will be 1 (Initial condition:1). So switch block will send the input-1 to the output which is equal to 1.
Afterward, output of switch block will come from input-3 connected to repeating sequence stair.
Repeating sequence stair will generate the sequence of 0 & 1 continuously.
So
Sample Time : 0 1 2 3 4 5 6 ....
Switch Blk Intput-1: 1 1 1 1 1 1 1 ....
Switch Blk Intput-2: 0 1 0 1 0 1 0 ....
Switch Blk output : 1 1 0 1 0 1 0 ....
NOT Blk output : 0 0 1 0 1 0 1 ....
Hope now it is clear.

Melden Sie sich an, um zu kommentieren.

Weitere Antworten (1)

Azzi Abdelmalek
Azzi Abdelmalek am 4 Sep. 2012
Bearbeitet: Azzi Abdelmalek am 4 Sep. 2012
try this
  1. set all sample time block to ts
  2. set initial value of unit delay block to 1
  35 Kommentare
Rahul kumar
Rahul kumar am 10 Sep. 2012
Any ideas azzi abdelmalek?

Melden Sie sich an, um zu kommentieren.