Simscape Simulation,External Force and Torque........ has its follower port rigidly connected to the world frame; it has no effect. You can configure this diagnostic in the Simscape Multibody Configuration Parameters dialog. [4 similar]
26 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Hi I am having issues with this simulation. I have followed Ryan Gordon And Michael Carone's example to be able to simulate my own QUadrotor. I am having this issue and I am unsure over how it can be resolved. https://www.youtube.com/watch?v=fpJZSQmqDVk&t=1206s
['Simulation_with_controller/External Force /Rotor 1'] : External Force and Torque 'Simulation_with_controller/External Force /Rotor 1/External Force and Torque' has its follower port rigidly connected to the world frame; it has no effect. You can configure this diagnostic in the Simscape Multibody Configuration Parameters dialog. [4 similar]
Component:Simulink | Category:Model warning
['Simulation_with_controller']: The following errors were found in the model Simulation_with_controller.
Caused by:
- ['Simulation_with_controller/External Force ']: 6-DOF Joint 'Simulation_with_controller/External Force /6-DOF Joint' has a rigid connection between its frame ports and physical signal inputs or outputs. This configuration is invalid. Resolve this issue in order to simulate the model.
- ['Simulation_with_controller/Ground Stop/FloorStop1']: 6-DOF Joint 'Simulation_with_controller/Ground Stop/FloorStop1/6-DOF Joint' has a rigid connection between its frame ports and physical signal inputs or outputs. This configuration is invalid. Resolve this issue in order to simulate the model.
- ['Simulation_with_controller/Ground Stop/FloorStop2']: 6-DOF Joint 'Simulation_with_controller/Ground Stop/FloorStop2/6-DOF Joint' has a rigid connection between its frame ports and physical signal inputs or outputs. This configuration is invalid. Resolve this issue in order to simulate the model.
- ['Simulation_with_controller/Ground Stop/FloorStop3']: 6-DOF Joint 'Simulation_with_controller/Ground Stop/FloorStop3/6-DOF Joint' has a rigid connection between its frame ports and physical signal inputs or outputs. This configuration is invalid. Resolve this issue in order to simulate the model.
- ['Simulation_with_controller/Ground Stop/FloorStop4']: 6-DOF Joint 'Simulation_with_controller/Ground Stop/FloorStop4/6-DOF Joint' has a rigid connection between its frame ports and physical signal inputs or outputs. This configuration is invalid. Resolve this issue in order to simulate the model.
Component:Simulink | Category:Block diagram error
2 Kommentare
Mohsen Nehsati
am 13 Aug. 2019
Hello
Did you get any answer for this error?.... I am facing tha same problem
Thanks
Shreyash Choudhari
am 29 Mai 2022
Hello
Did you get any answer for this error?.... I am facing tha same problem
Thanks
Antworten (0)
Siehe auch
Kategorien
Mehr zu Multibody Dynamics finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!