how to solve this problem
10 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
An error occurred while running the simulation and the simulation was terminated
For block 'PMSM_SMO_atan/SVPWM_control/Subsystem2/Multiport Switch', control port value '0' is not in between '1' and '6'. To suppress this message and use the default port, you can change the settings of 'Diagnostic for default case' to 'None'
Component: Simulink | Category: Block error
2 Kommentare
Walter Roberson
am 4 Mär. 2019
Either figure out why the control port was 0, or else make the change they suggest.
Sai kartheek Chavali
am 4 Mär. 2019
PMSM_SMO_atan/SVPWM_control/Subsystem2/Multiport Switch
what is the model functionality?
Antworten (1)
Sabin
am 5 Jun. 2025
Without a model is not possible to point to the root cause but the problem is, as the error points out, the control port of a multiport switch that is 0 but the parameter 'Data port order' is set to One-based contiguous (this means that the out of range condition is: the control input is less than 1 or greater than the number of data inputs.).
0 Kommentare
Siehe auch
Kategorien
Mehr zu Electrical Block Libraries finden Sie in Help Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!