Engine cooling system (thermal fluid)

9 Ansichten (letzte 30 Tage)
Shivam Atre
Shivam Atre am 24 Jan. 2019
In the engine cooling system, we have bypass hose as pipe(TL) so the error i am getting is the outlet pressure according my values cannot run the simulation and it is showing that at the outlet port (B) the pressure is less than th minimum valid pressure.
So how can i change the minimum pressure defined in the pipe (L) or how can i rectify this problem.
  2 Kommentare
SITTI NUR ATHIRAH ALAM SHAH
SITTI NUR ATHIRAH ALAM SHAH am 24 Nov. 2020
Hey..have you find the solution? . cause i still not get it
sai srinivasa chaitanya Dasari
changing the pipe area can vary pressure try to change it if pressure is your concern

Melden Sie sich an, um zu kommentieren.

Antworten (1)

Just Us
Just Us am 24 Jan. 2019
There are two possibilities to overcome this problem: Either you enlarge your fluid flow, which means that you raise the "input pressure" or you go to your fluid properties and define temperatures and densities and internal energies and so on for lower pressures than occuring at port B