Add dead time in Simulink
242 Ansichten (letzte 30 Tage)
Ältere Kommentare anzeigen
Jiaxiu Dong
am 14 Dez. 2018
Kommentiert: Lazuardi Agung
am 17 Dez. 2022
Hi, I am trying to control an H bridge cell. So in order to avoid two swithes turn ON at the same time, I need to add the dead time. I would expect a similar waveform as below. Does anyone konw how to achieve this in Simulink? Thank you so much!
0 Kommentare
Akzeptierte Antwort
Rick Hyde
am 12 Nov. 2021
We now have the Gate Driver and Half-Bridge Drive blocks in Simscape™ Electrical™ which allow you to specify dead-time/blanking time in a numerically efficient way. Please see the screenshot below. Hope you find this solution useful.
Rick
2 Kommentare
Nueraimaiti Aimaier
am 10 Okt. 2022
Hi,
This is helpful, thanks. However, what kind of ports (or devices) should be connect to the output of Driver? I used Simulink-PS converter for the input, it can be connected. But, at the output, I used PS-Simulink converter and it cannot connected to Simulink signal MOSFET.
Rick Hyde
am 17 Okt. 2022
The output pins of the driver block should be directly connected to Simscape electrical ports on semiconductor device models in the Simscape Electrical library.
Weitere Antworten (3)
Yonghui Xu
am 28 Mär. 2019
Add following blocks to your switching signal path and you can set the deadtime by setting the time delay of the transport dealy block.
2 Kommentare
Mark Sherstan
am 14 Dez. 2018
try: Transport Delay
5 Kommentare
Zoe Blatsi
am 4 Jun. 2020
Hello,
I tried this for my discrete time PWM model:
and it seems to be working alright:
you could even configure a variable delay in the "delay" block settings.
I hope that helps.
Zoe
Lazuardi Agung
am 17 Dez. 2022
thanks, for solving my problem. by just adding transport delay block we can easyly add dead time control
0 Kommentare