No simlog variable for power loss analysis
Ältere Kommentare anzeigen
I am trying to estimate the dissipated power in the rectifiers and converters in my Simulink model. I have removed all algebraic loops and get no errors (only 3 warnings) when I run sim(model). I have all of the right settings for simulation data-logging and the sim command definitely simulates the model. However, at the end of it there is no simlog variable in my workspace. I have tried to use the command line to view it and that returns 'undefined function or variable'. My Matlab version is R2016b. Please let me know if there is something I'm missing that's causing this.
Thanks
Antworten (1)
Sabin
am 13 Dez. 2024
0 Stimmen
Two things you can check:
- In Configuration Parameters/Simscape the ‘Log simulation data’ is not set to ‘None’.
- If ‘Log simulation data’ is not set ‘None’ check in Solver Configuration -> Data Import/Export if the Parameter ‘Single simulation output’ is enabled or disabled. If ‘Single simulation output’ is enabled then you will have a single object as output, by default called out. In this situation to access the simlog you need to access out.simlog.
Communitys
Weitere Antworten in Power Electronics Control
Kategorien
Mehr zu Data Logging finden Sie in Hilfe-Center und File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!